All articles
7 min read

Medical Device Inventory Management: Register and Recall Drill

Medical device inventory management in India means keeping a register that records lot and expiry on every purchase and sale, then proving it with a timed recall drill that lists every customer.

By Praveen Nune, Co-Founder & CEO · Updated 19 Nov 2026

A medical device stockist in an Indian storeroom checks a boxed device on a shelf while holding a clipboard.

Key takeaways

  • A registered device seller in India must keep purchase and sale records showing lot or batch number and expiry date (where applicable). Rule 87B(5) of the Medical Devices Rules, 2017 requires it, and Rule 87B(7) requires the records to be kept for at least two years from the last entry.
  • The real test of your system is a timed recall drill: pick a lot, list received, on hand, sold and customers, and reconcile to zero.
  • Store expiry as the last day of the printed month. Rule 44 defines expiry that way.
  • Unique device identification (UDI) is not yet something you can plan a date around. Rule 46 applies it only from a date the Central Government specifies by order.
In this article
  1. 1What must a medical device inventory register record in India?
  2. 2How do you run a recall drill on your medical device stock?
  3. 3How do you choose a lot and start the clock?
  4. 4How do you reconcile a lot to zero?
  5. 5What counts as a pass or fail on the shelf count?
  6. 6What do Indian rules require beyond lot and expiry on the medical device inventory register?
  7. 7Which register mistakes fail the drill?
  8. 8How does Arka Inventory handle lots, expiry and serial numbers?
  9. 9Frequently asked questions

A recall notice names a lot, not a customer. Only the seller's register can say who holds it.

When that register stores only product name and quantity, a failed trace has a plain cost. You cannot tell which customers hold the affected units, so you either contact every buyer of that device or leave the question unanswered. A Medical Device Officer (the State inspector) who reads your records against Rule 87B(5) finds the required lot and expiry fields missing.

A register that stores lot and expiry on every purchase and sale line answers the same question in minutes, from the record alone, without a call to the warehouse. It also shows which lots are close to expiry, so you can act before they reach a customer.

This page gives you the register columns, a recall drill with pass and fail marks, and the mistakes that fail the drill. It is written for sellers and distributors holding a Form MD-42 registration certificate; manufacturers should check the record rules under their own licence. Hospital equipment registers are a different job.

What must a medical device inventory register record in India?

A registered seller's register must show, for every purchase and sale, the device name and quantity, the manufacturer or importer's name and address, the batch or lot number, and the expiry date where applicable. That is Rule 87B(5) of the Medical Devices Rules, 2017, published by the Central Drugs Standard Control Organisation (CDSCO). The register can be an invoice file, a ledger or software. This page uses "lot" for both lot and batch numbers.

Rule 87B applies to holders of the registration certificate (Form MD-42). If you sell under a different licence, check the conditions printed on your own licence.

Use these columns (rules as of November 2026):

ColumnWhat to enterBasis
Device name and modelAs printed on the labelRule 87B(5); Rule 44(a)
Quantity in and outEvery purchase and every saleRule 87B(5)
Manufacturer or importerName and addressRule 87B(5)
Lot or batch numberExactly as printed after "Lot No." or "Batch No."Rule 44(g); Rule 87B(5)
ExpiryThe month and year printed, stored as the last day of that monthRule 44(e); Rule 87B(5)
No-expiry flagYes for stable-material non-sterile devices (stainless steel, titanium) and for equipment and instrumentsRule 44(e) provisos
Storage location and conditionWhere the lot sits, and the temperature or light condition the label requiresRule 87B(2)-(3)
Last entry dateKeep the record at least two years after itRule 87B(7)
Serial numberOne line per unit for serialised devicesOur recommendation
Supplier invoice number and dateFor each receiptOur recommendation
Customer and sale invoice number, per lotOn every sale lineOur recommendation

The last three columns are not in the rule text. They are what makes the drill below possible: without a customer attached to a lot on each sale line, you cannot answer a recall.

How do you run a recall drill on your medical device stock?

A recall drill is a timed test: pick one lot, produce its full history from the register alone, and reconcile it to zero. Run it on three lots, a fast mover, a slow mover and one that has moved between locations, because each breaks the register differently.

How do you choose a lot and start the clock?

  1. Choose a lot received at least six months ago that has had sales since.
  2. Start a timer. Without phoning the warehouse, write down units received, units on hand by location, units sold (each with invoice number and customer), and units written off or returned to the supplier.

How do you reconcile a lot to zero?

  1. Reconcile. Received must equal on hand plus sold plus written off.

What counts as a pass or fail on the shelf count?

  1. Count the shelf. Physically count that lot at one location and compare it with the register.
  2. Score it.
    • Pass: the reconciliation is exact, the shelf count matches, every sold unit has a customer and an invoice, and the full trace is written down within 60 minutes (our recommendation).
    • Fail: any unit unexplained, any sale line without a customer, any lot number typed two different ways, or a trace that takes more than one working day.

Stock you place with hospitals on consignment, or hold for others, belongs in a separate section of the register. Our guide to consignment inventory shows how to keep it apart from stock you own.

Two colleagues at a desk compare a printed register against a boxed device while a timer sits between them.
A recall drill is done against the clock, with the register as the only guide to where one lot went.

What do Indian rules require beyond lot and expiry on the medical device inventory register?

Indian rules ask a seller for purchase and sale records with lot and expiry, while UDI has no fixed date. Three details of the Indian rules matter for your register:

  • Lot and expiry are already mandatory. Rule 87B(5) asks for them on every purchase and sale. They are not a "best practice" you adopt later.
  • UDI has no fixed date. Rule 46 says every approved device shall bear a UDI "with effect from such date as the Central Government may, by order specify". We would add a UDI field to the register now so the data is there when the order applies.
  • Recall duties sit with the maker, but the customer list sits with you. Rule 89 obliges the manufacturer or authorised agent to withdraw an unsafe device, and Rule 2(zp) defines recall to include retrieval by a supplier. Our reading: the manufacturer can name the lot, but only the seller's register can say who has it.

Which register mistakes fail the drill?

Five faults make a register fail the recall drill, and each is fixed when the entry is made.

  • Free-text expiry. "03/27", "Mar-27" and "March 2027" will not sort or filter. Store one date, the last day of the printed month, as Rule 44(e) defines it.
  • Lot recorded on receipt but not on the sale line. Then you know what came in, not who got it.
  • Mixed lots on one line. Two lots of the same model entered as one row make reconciliation impossible. One lot per line.
  • Transfers without a record. Stock moved between a warehouse and a branch changes location but must keep its lot number.
  • No review of near-expiry stock. Each month, list the lots expiring in the next 90 days. The 90 days is our suggestion, not a rule. Decide what you do with them: return to supplier, discount, or write off.

A spreadsheet can pass the drill for a few dozen lots if one person keeps it disciplined. Our guide to a Goods and Services Tax (GST)-ready stock register in Excel covers the layout. If your books run in Tally, run the Tally stock health check first.

A receiving table shown twice: mixed device boxes on the left and the same boxes sorted into separate tagged rows on the right.
Keeping each lot on its own line is what lets a sale be traced back to the right batch.

How does Arka Inventory handle lots, expiry and serial numbers?

We track every item by lot or batch, expiry date and serial number, and keep location and quantity on the same record. Each receipt, transfer and sale updates that record, so you can build a custom report of a lot's receipts, locations and sales from the same record. Lot and serial tracking is part of our Enterprise plan.

What that gives a device seller:

  • Receiving. Record the lot, expiry and serial number at the dock, using barcode or QR scanning.
  • Locations. Multiple warehouses and bins, with putaway (moving received stock to its storage bin) and picking.
  • Alerts. Low-stock and inventory-movement alerts.
  • Picking. FIFO (first in, first out) picking, so the oldest receipt leaves first.
  • Reports. Custom reports and dashboards.
  • Books. Integrations with Salesforce, QuickBooks Online and Tally.

In our June 2026 case study, a home healthcare provider with 14 locations reported that the time to locate a serialised unit fell from 12-15 minutes to 2-3 minutes. The study measures finding a unit in stock, not tracing a lot to customers.

You can test this yourself. We offer a 15-day free trial with full access and no credit card. Onboarding takes at least two weeks, depending on how ready your product, warehouse and lot data are. Load three real lots, run the drill, and judge the result by the pass and fail marks above. As of November 2026, we list Basic at $199 a month and Advance at $499 a month, both billed yearly, and lot and serial tracking is in the Enterprise plan, which is quoted on request (pricing). When you book a demo, ask us to show the lot-to-customer trace on your own data. Book a demo or send us your question and we will reply.

Talk to our team

Leave your details and we'll get back to you.

Frequently asked questions

Medical equipment inventory is the register of devices a facility owns, with identity, location, warranty and maintenance status. Hospitals keep it for assets such as monitors and ventilators. Our hospital inventory management guide covers that case; this page covers stock that is bought and sold.

Yes. Rule 87A requires a registration certificate (Form MD-42) before you sell, stock or distribute medical devices.
Not yet. As of 19 November 2026 Rule 46 applies only from a date the Central Government specifies by order, and no date has been published.
Keep them for at least two years from the last entry in the register, under Rule 87B(7).
A spreadsheet is enough if it passes the recall drill: exact reconciliation, a customer on every sale line, and a fast trace. It usually stops passing when you add locations, serial numbers or more than one person editing. Run the drill monthly to see when that happens.

Sources

  1. 1.Medical Devices Rules, 2017, as amended to GSR 777(E) of 14 October 2022, Central Drugs Standard Control Organisation, Ministry of Health and Family Welfare
  2. 2.Medical Devices Rules, 2017 (CDSCO rules page), Central Drugs Standard Control Organisation
  3. 3.Operational Excellence in Healthcare Inventory Management, Arka Inventory case study, June 2026

Keep reading

Arka Inventory.

© 2026 Arka Inventory

Powered by PageLens.ai

Get in touch — we'd love to help.

Request a Demo